Probe Temperature and Humidity Transmitter CAEL-S16 RS485 Modbus

คุณสมบัติสินค้า:

CAEL-S16/-40..120°C/0-100%RH/RS485/Probe Type

หมวดหมู่ : TEMPERATURE & HUMIDITY Sensor & transmitter

แบรนด์ : SERIAL

Share

คุณสมบัติ

Humidity

Measurement range                                                         0 ... 100 %RH Accuracy (including non-linearity,hysteresis, andrepeatability)
 
CAEL-S16A                                                                         ±1.5%RH@25℃ (20 … 80%RH)
                                                                                             ±2%RH@25℃ (0 … 20/80 … 100%RH)
CAEL-S16                                                                           ±2%RH@25℃ (20 … 80%RH)
                                                                                             ±3%RH@25℃ (0 … 20/80 … 100%RH)
Temperature coefficient (from 0°C to 80°C)                typ. ±0.02%RH/℃
Humidity Hysteresis                                                         ±1%RH
Long term drift                                                                  < 0.25%RH/year
Response time T63                                                          8 second (at 1m/s air flow)
 
Temperature
 
Measurement range                                                                                      -40 ... 1200 ℃
Accuracy (including non-linearity, hysteresis, and repeatability)           ±0.4℃@25℃
                                                                                                                           ±0.7℃(-40...5℃ )
                                                                                                                           ±0.3℃(5...60℃ )
                                                                                                                           ±0.9℃(60...120℃ )
Long term drift                                                                                                < 0.02℃/year
 

Analog output

Voltage version                                                                                                 0 ... 1 V / 5 V / 10 V
Accuracy of analog outputs at +25 °C                                                          ±0.1% full scale
Temperature dependence                                                                             ±0.005%/°C full scale
External loads                                                                                           0 ... 5 V and 0 ... 10 V outputs RL > 10  kohm

RS485 Modbus RTU (Standard)

ID                                                                          1…247

Baud rate                                                            9600/19200/38400/57600/115200

Data format                                                        N81/N82/E81/E82/O81/O82

Psychrometric calculations

(Td) dew point temperature, (A) absolute humidity,
(Tf) frost/dew point temperature, (R) mixing ratio,
(S) enthalpy, (Tw) wet bulb temperature,
(E) water vapor pressure

Power supply

Analog output 0…1V                                             5 ... 28 VDC                                                                    
Analog output 0…5V / 10V                                 15 ... 28 VDC
RS485 version                                                      12 … 28 VDC

Power consume (25 °C, V+ 24 VDC)

Analog version                                                     typ. 3mA
RS485 version                                                       typ. 3mA

Mechanics

Filter material                                                         PC, Polycarbonate
Probe material                                                       brass nickel-plated
Probe pressure                                                      10bar
Housing classification                                           IP65
Cable                                                                        M12 4-pin 2M female

Operation temperature                                               -40 ... 120 °C (-40 ... 248 °F)

Electromagnetic compatibility

EN61326-1:2013 Emission
CISPR11:2009+A1:2010 Group 1 Class B
EN61326-1:2013 Immunity
IEC 61000-4-2:2008
IEC 61000-4-3:2006+A1:2007+A2:2010
IEC 61000-4-8:2009

 

การนำไปใช้งาน

ตรวจวัดค่าอุณหภูมิความชื้นได้หลากหลายเช่น ตรวจวัดอุณหภูมิความชื้นคลังเก็บสินค้าป้องกันสินค้าเสียหาย , ตรวจวัดอุณหภูมิความชื้นห้องเก็บยาและเวชภัณฑ์ซึ่งต้องควบคุมดูแลเข้มงวด , ตรวจวัดอุณหภูมิความชื้นระบบ HVAC อาคารเพื่อควบคุม

เงื่อนไขอื่นๆ

  • สินค้ารับประกัน 1 ปี  (สงวนสิทธิ์การรับประกันสินค้ากรณีลูกค้าต่อไฟใช้งานผิดประเภท)
  • ฟรี! ค่าขนส่ง
  • ให้คำแนะนำหลังการขาย
 

Documentation

___________________________________________________________________________________

CAEL-S16 DATASHEET                                                                                      Download

___________________________________________________________________________________

CE CERTIFICATE                                                                                                 Download

___________________________________________________________________________________

Modbus RTU protocol                                                                                       Download

___________________________________________________________________________________

Modbus RTU protocol, for FW v6.0.0 and newer                                          Download

___________________________________________________________________________________

 

Software

___________________________________________________________________________________

CAEL Configurator_v7.0.1                                                                       Download

 